Name |
Main Technical Parameters |
Genset model |
CCFJ250J-W2 |
Power supply type |
Three-phase AC |
Rated power kW |
250 |
Rated voltage V |
400 |
Rated current A |
451.1 |
Rated frequency (Hz) |
50 |
Rated power factor(COSφ) |
0.8(Lag) |
Rated speed r/min |
1500 |
Absolute value of steady-state voltage regulation % |
≤2.5 |
Absolute value of transient voltage deviation (%) |
Sudden unloading 60% Rated current |
≤20 |
Sudden load 60% Rated current |
≤15 |
Voltage stabilization time (s) |
≤1.5 |
Absolute value of voltage fluctuation rate % |
≤1 |
Absolute value of transient speed regulation % |
Sudden load 0-50% |
≤10 |
Sudden load 50-100% |
Sudden unloading 100%-0 |
Transient speed regulation stabilization time (s) |
≤5 |
Steady-state speed regulation % |
≤5 |
Absolute value of speed fluctuation rate% |
≤0.5 |
Insensitivity of genset speed governing system % |
≤0.5 |
Fuel consumption rate under rated conditions (g/(kW·h))) |
≤205 |
Specific oil consumption g/(kW·h) |
≤0.35 |
Fuel grade |
Summer: 0#, 10# light diesel of GB 19147-2016 premium grade or first grade;; |
Winter: 0#, -10#, -20# and -35# light diesel of GB 19147-2016 premium grade or first grade (selected based on the ambient temperature)) |
Oil grade |
Summer: 40CF, 15W/40CF; |
Winter: 30CD, 10W/30CD or other diesel engine oil that is not inferior to Grade CF in GB 11122-2006 and suitable for the environment. |
Start mode |
Electric start |
Cooling mode |
Internal circulation:Closed circulating water cooling,External circulation:Open water cooling |
Connection mode of motor winding |
Three-phase four-wire |
Operating mode of genset |
Continuous |
Operating environment conditions |
Ambient temperature |
45°C |
Outboard water temperature |
32°C |
Inclination angle |
Hell: 15°; roll: 22.5°; trim: 7.5°; pitch: 10° |
Temperature rise |
Thermal classificationA |
55°C |
Measurement method R |
Short circuit |
The alternator and its excitation system can maintain at least 3 times the rated current for at least 2s under steady-state short-circuit conditions. |
Overload |
50% overcurrent; 2 min |
Fuel engine model |
YC6MJ410L-C24 |
Rated power of diesel engine (kW) |
300 |
Alternator model |
SB-HW4.D-250 |
(SAE1-14) |
Rated power of motor (kW) |
250 |
Genset weight (kg) |
2120 |
Diemension(Length × width × height) mm |
2500×1035×1385 |
Note: Dimension (L*W*H) may vary with the configuration. |